Bellwether Owners · Main Blower Effort Cleaning group
Cleaning before clearing the blower warning — Bellwether Owners

Nocturne Café · Equipment help

Bellwether Shop Roaster

Full clean before clearing the blower warning

Item 3 of the fix, step by step, with Bellwether’s real photos. Mirrored 2026-11-18.

01

Empty the chaff & water collector

Countertop

Twist off the collector

Twist the Chaff/Water Collector left to drop it out, pour the water into a drain, then invert it over a bin to dump the chaff. Lock it back by raising it in with the handle slightly left and rotating right.

Source: Daily Maintenance

Continuous

Slide out the handled tray

Pull the lockbar outward and slide out the handled tray; empty the separate chaff and water bins, reinsert, push the tray back in and push the lockbar in.

Source: Daily Maintenance

02

Vacuum both prefilters

Remove the two Prefilters from beneath the roasting drum, thoroughly vacuum both sides, and reinsert. (Every 3 roasts Countertop / 13 roasts Continuous.)

Source: Daily Maintenance

03

Soak prefilter mesh in Cafiza (weekly)

Push the two mesh pieces up out of the bracket (side nearest the handles), soak in coffee-machine cleaner (Cafiza, Joe Glo), air-dry, reassemble and refit.

Source: Weekly Maintenance

04

Vacuum above the cooling tray & the cooling-brick ducts

Remove the Bean Cooler (Countertop) or the Valence/Autobucket (Continuous) and the Prefilters; vacuum inside the cooler and the area above it — especially the sealing surface and the ducts to the Cooling Bricks. Do not damage the Bean Cooler temperature probe (circled blue).

Source: Vacuuming Above The Cooling Tray · Weekly Maintenance

05

Vacuum the chaff separator (cyclone)

Countertop

Remove the chaff can

Remove the chaff can (rotate left, lower out), vacuum its internals and up into the chaff cyclone above where it seals, then replace the can.

Source: Weekly Maintenance · Vacuuming The Chaff Cyclone & Chaff Tube

Continuous

Disconnect the chaff tube

Towel in the water-collection cup, rotate the connecting ring left to disconnect, vacuum the tube bottom and top and up into the cyclone. Reassemble so the silicone is fully secured and the collar tight — no air leaks.

Source: Weekly Maintenance · Vacuuming The Chaff Cyclone & Chaff Tube

06

Clean & reseat the inlet screen

Members-only · no public photo

No real image available.

Bellwether’s inlet-screen article is members-only (login required), so its photos could not be downloaded. Sign in to your Bellwether account to view it.

Open “Cleaning and Reseating the Inlet Screen”

Source: Cleaning and Reseating the Inlet Screen (members-only)

07

Reseat the seals — chaff collector, chaff boot/collar, bean-cooler latch

Chaff collector: when correctly locked (Countertop) you should see a gap beneath it; on Continuous, if the seal doesn’t feel secure add a spacer under the chaff container. Chaff boot: fully reseat the silicone boot lip onto the Chaff Connector. Latches seal the collectors “to avoid any leaking of hot air, steam or gasses.”

Source: Daily Maintenance · Vacuuming The Chaff Cyclone & Chaff Tube · Shop Roaster Operator Manual (05-01-2026), pp. 12–13 (component diagrams)